Characteristics of the cable BPDO 0,5
1 . A vein - a copper tinned wire;
2. Insulation-polyethylene;
3. Insulation - fluoroplastic;
4. Screen - copper tinned wire.
Electrical insulation resistance of 1 m of wire - for less than 1 10 'Mam.
Test voltage of alternating current of frequency 50 Hz - 2200 V.
The wires are designed to work in the temperature range from minus 60 to +1050С.
The cable is resistant to relative humidity of air up to 98% at a temperature of + 350 ° C, lowered to 670 Pa (5 mmHg) and increased to 300 kPa atmospheric pressures, salt fog, solar radiation, precipitation, oil and gasoline.
The construction length is not less than 25 m.
Service life - 15 years
The working range of different sections of this type of product is from -60 to 105 ° C. The TED-0.5 wire is used for intra-part or inter-hardware applications in aeronautical engineering. Operating alternating voltage 600 V and 850 V DC. The wire tolerates acoustic noises, vibration and air fluids well.
| Purpose | |
| Aircraft | IL-76 |
| Helicopter | MI-8/171 |
| Wire Specifications | |
| Current load, A | 750V |
| Cut | 0,5 |
| Diameter | 1,8 |

Russian
English